Skip to content

Classic mode

Classic is a session at one fixed temperature for a set time. It behaves the way the device always has, so nothing changes for you, and the official Focus V app still works with it.

There are five presets for each atomizer type, concentrate and flower, plus a custom value. Each preset is a temperature and a duration, and can have a name. It is the same table the Focus V app reads and writes, so edits made in either app show up in the other.

  • On the one-button devices, 1 click steps to the next slot. The light shows the slot’s colour and a count.
  • On the Carta 2, hold on the home screen opens the slot picker.
  • Edit presets from the web app, or by dialing a value on the device:
    • One-button: hold for 1 s, then each click adds 5 °F (2 °C). Hold again to save.
    • Carta 2: + and − on the home screen.

The device enforces these, whatever an app asks for.

Device Flower Concentrate Flower length Concentrate length
Carta 2 275–500 °F 365–635 °F 120–240 s 20–120 s
Carta Sport 275–500 °F 365–635 °F 120–240 s 20–120 s
Aeris 275–500 °F 365–600 °F 120–240 s 20–60 s

In °C the flower range is 145–260 on all three, and concentrate is 185–335 on the Carta 2 and Sport and 185–315 on the Aeris.

If a value is outside the limit, the device uses the nearest allowed value and the web app shows you what it stored.

  • +10 s extends the session by ten seconds, once per session (like the factory firmware).
  • Stop is always one click away.
  • On the Carta 2, + and − change the live temperature.

Quick heat is the factory cleaning heat. On the one-button devices it is “click, then hold for 10 seconds” from off. It is not a heat to maximum: it warms the chamber to a fixed temperature and holds it until you press the button.

Device Quick heat holds
Carta 2 185 °F (85 °C)
Carta Sport and Aeris 194 °F (90 °C)

The official app sees your Classic presets as its own temperature table, and sees a running session as a normal session.